تعیین SSD موثر پرتو الکترونی دستگاه شتابدهنده واریان بخش رادیوتراپی بیمارستان گلستان اهواز Determination of Effective Source-Surface Distance for Therapeutic Electron Beams for Varian2100 C/D accelerator to treatment in cancer patients in radiotherapy department of Ahvaz-Golestan hospital

غریب رضا, الهه (2015) تعیین SSD موثر پرتو الکترونی دستگاه شتابدهنده واریان بخش رادیوتراپی بیمارستان گلستان اهواز Determination of Effective Source-Surface Distance for Therapeutic Electron Beams for Varian2100 C/D accelerator to treatment in cancer patients in radiotherapy department of Ahvaz-Golestan hospital. Masters thesis, دانشگاه علوم پزشکی و خدمات بهداشتی درمانی جندی شاپور اهواز,دانشکده پزشکی

[img]
Preview
Text
m108135.pdf.pdf

Download (1MB) | Preview

Abstract

زمینه و هدف: برای تخمین فاکتور خروجی و توزیع دوز در محاسبات دوز در الکترون تراپی نیاز است که نقطه‌ای برای منبع تابش الکترونی در نظر گرفته شود. هدف از این تحقیق تعیین فاصله مؤثر سطح تا پوست دستگاه شتابدهنده خطی الکترون و میزان وابستگی آن به انرژی و عمق است. روش بررسی: دستگاه شتابدهنده خطی Varian Clinac 2100CDبا انرژی های الکترونی 4 تا MeV 15، اپلیکاتور الکترونی cm2 2020، SSD های اسمی 97 تا cm 113 با ارتفاع هوای بین اپلیکاتور و سطح تابش به ترتیب 2 تاcm 18 به کار رفت. با استفاده از دزیمتر یونیزان فارمر cc 13/0 در داخل فانتوم آب (cm3 50) درصد دوز عمقی اندازه گیری شد و SSDeff با اعمال قانون عکس مجذور فاصله محاسبه شد. یافته ها: مقدار √I2/Ig با ارتفاع حجم هوای بین انتهای اپلیکاتور تا سطح فانتوم تقریباً بطور خطی افزایش می یابد. در یک عمق با PDD مشخص، با افزایش انرژی SSDeff افزایش می یابد و نیز در یک انرژی مشخص با افزایش PDD نیز این افزایش مشاهده می شود. برای PDD 100%، SSDeff انرژی های 4 ،6 ،9 ، 12 و MeV 15 به ترتیب برابر 79، 91، 92، 93 و cm92 محاسبه شد. نتیجه گیری: با استفاده از PDD عمق دوز ماکزیمم و رابطه عکس مجذور فاصله، SSDeff مورد نیاز برای محاسبه توزیع دوز باریکه الکترونی را می توان محاسبه کرد. Background and aim: to estimate the output factor and distribution of dose in dose calculation in electron therapy a point must be considered for a source of electron radiation. The aim of this study was to determine the effective distance of the fountain from the surface (SSDeff) of Electron Linear Accelerator machine and the extent of its dependence on energy and depth. Materials and Methods: a Varian Clinac 2100CD linear accelerator machine with electron energies of 4 to 15 MeV, electron applicator sizes of 20× 20 cm2, nominal SSDS of 97 to 113 cm with height air between the applicator and radiation levels from 2 to 18cm was used in this study. Using dosimeter ionizing Farmer 0.13 cc in the water phantom (50cm3) the percentage of depth dose was measured and by applying the inverse square law the SSDeff was calculated. Results: the amount of √I2/Ig with the height of volume of air between the end of the applicator up to the level of the phantom increases almost linearly. At a depth with the certain PDD by increasing energy the SSDeff is increased as well as in a distinctive energy by increasing the PDD also this rise can be observed. For the 100%PDD, the SSDeff of energies of 4, 6, 9, 12 and 15 MeV was calculated respectively equal to 79, 91, 92, 93 and 92 cm. Conclusion: using the maximum dose depth PDD and inverse square relationship, the SSDeff required for calculating the dose distribution of the electron beam can be calculated

Item Type: Thesis (Masters)
Keywords: فاصله مؤثر چشمه تا سطح ، فاکتور خروجی، الکترون تراپی The effective source surface distance (SSDeff); Output factor; Electron therapy
Subjects: R Medicine > R Medicine (General)
Divisions: Faculty of Medicine, Health and Life Sciences > School of Medicine
Depositing User: آقای بهرام سوسنی غریب وند
Date Deposited: 15 May 2017 04:50
Last Modified: 15 May 2017 04:50
URI: http://eprints.ajums.ac.ir/id/eprint/7222

Actions (login required)

View Item View Item